Read it top to bottom the first time, then return to the sections that match your question. In short, use this home battery glossary like an installer reads a spec sheet: Battery Basics for energy and chemistry, System and Installation for the inverter side, and Standards and Certification for the compliance side.

Battery Basics in This Home Battery Glossary

kWh (kilowatt-hour)

A unit of energy, the kilowatt-hour. In home storage it describes how much electricity a battery can hold. A 10 kWh battery runs a 1 kW load for about ten hours, ignoring efficiency losses. Usable energy always sits below nameplate capacity, because the battery does not discharge to zero (see depth of discharge).

kW (kilowatt) and kVA

In short, a unit of power — how fast energy flows. In addition, the battery’s kW rating caps how much load it can carry at one moment. Keep capacity (kWh) and power (kW) separate: a system can be large in energy yet small in power.

LiFePO4 / LFP (lithium iron phosphate)

A lithium iron phosphate chemistry using an iron-phosphate cathode. For that reason, LFP dominates home storage: it stays thermally stable, delivers a long cycle life and holds up under daily deep discharge. Its energy density trails nickel-based chemistries, so LFP home batteries run physically larger for the same capacity.

BMS (battery management system)

Next, the electronics that monitor and protect a battery. A BMS measures cell voltage and temperature, balances the cells, prevents over-charge and over-discharge, and reports state of charge to the inverter. To gauge protection depth, count the separate safety functions a BMS implements.

Cell, module, pack

Next, the three levels of battery construction. A cell is the smallest unit that stores energy. The cells then group into a module, and the modules assemble into a pack — the finished enclosure you install in a home.

Cell balancing (passive and active)

Cell balancing equalises charge across cells so the weakest cell does not limit the whole pack. Passive balancing dissipates excess energy as heat. However, active balancing moves energy between cells, and it proves more efficient but more complex.

DoD (depth of discharge)

DoD matters because it sets the usable energy: the percentage of capacity you actually use on a cycle. A battery running to 90% DoD delivers more usable energy than one limited to 80%, at some cost in cycle life. Typically, manufacturers publish the DoD at which they measure the cycle-life figure.

SoC (state of charge)

Next, how full the battery is, expressed as a percentage. For instance, think of it as the battery equivalent of a fuel gauge.

C-rate

Next, the speed at which a battery charges or discharges relative to its capacity. For example, a 1C rate on a 10 kWh battery means 10 kW. Home batteries usually operate well below 1C, which reduces stress and heat.

Cycle life

In addition, the number of charge–discharge cycles a battery completes before its capacity falls to a stated percentage of the original — typically 80% or 60%. Manufacturers always quote cycle life at a specified temperature and depth of discharge, so do not compare figures from different conditions directly.

Round-trip efficiency

The share of energy you put into a battery that you take back out, after conversion and storage losses. Expressed as a percentage, the remainder leaves as heat.

Calendar ageing

Capacity loss that accumulates over time regardless of how often the battery cycles. In practice, temperature drives it, along with the average state of charge the battery sits at.

Thermal runaway

In short, a self-sustaining temperature rise inside a battery cell. Therefore, it is the central safety concern for lithium batteries, and it explains why LFP chemistry, cell-level testing and enclosure design matter. Standards such as UL 9540 and IEC 62619 exist largely to test resistance to it.

System and Installation in This Home Battery Glossary

The system section of this home battery glossary covers the inverter side and how the battery connects to solar and grid.

Hybrid inverter

Then, an inverter that manages solar panels, a battery and the grid through one unit. In addition, it charges the battery from solar, discharges it to the house, and exports or imports from the grid.

AC-coupled vs DC-coupled

These terms describe how a battery connects to a solar system. DC-coupled means the battery shares the solar array’s DC bus, which avoids one conversion step. AC-coupled means the battery connects on the AC side through its own inverter, which makes adding storage to an existing solar installation easier.

MPPT (maximum power point tracking)

The control that continuously adjusts a solar array’s operating voltage so it delivers its maximum available power under changing light and temperature.

Off-grid, on-grid and grid-tied

First, on-grid systems operate alongside a utility supply. By contrast, off-grid systems operate with no utility connection, so you must size them for the worst-case period without sun. In practice, most home batteries run on-grid with backup capability.

Backup power and transfer time

Backup power keeps selected circuits running during a grid outage. Transfer time is the gap between the grid failing and the battery taking over, and sensitive electronics need a short one.

Peak shaving

The battery discharges during the periods when electricity is most expensive, which reduces the peak power drawn from the grid. In addition, on tariffs with a demand charge, shaving the peak lowers the bill directly.

Time-of-use (TOU) arbitrage

You charge the battery when off-peak electricity is cheap and discharge it during peak-rate hours. The value depends on the spread between the two rates and on how many cycles the battery performs.

Self-consumption

Instead of exporting solar generation to the grid, self-consumption means using it on site. A battery raises the self-consumption rate by storing midday surplus for the evening, when household demand peaks.

VPP (virtual power plant)

A network of home batteries coordinated by a utility or aggregator to act as one large resource — for example, discharging together during a system-wide peak. Participation requires a battery with suitable communications and a supporting tariff.

IP rating

An ingress-protection rating for enclosures, written as IP followed by two digits. The first digit covers solids, the second covers water. An IP54 battery resists dust ingress and splashing water, which allows installation in a garage or sheltered outdoor position rather than a dry indoor room only.

Form Factors in This Home Battery Glossary

This part of the home battery glossary covers the physical formats and how capacity grows.

Stackable battery

A modular design where identical modules stack vertically, so you choose capacity by the number of modules rather than by buying a different product. You size a stack to the household at installation and extend it later as demand grows.

Wall-mounted battery

A slim enclosure fixed to a wall. It saves floor area, which suits garages and utility rooms where space is tight, and it keeps the battery clear of standing water.

Floor-mounted battery

A freestanding enclosure that rests on the floor. It supports larger capacities and heavier modules than a wall fixing does, and installers often pick it where a wall is not structurally suitable.

Rack-mount battery

A battery built to standard rack dimensions and installed in a cabinet. Installers choose it where several units combine for higher capacity.

Parallel expansion

You raise total capacity and power by connecting additional battery units to an existing system. The inverter and the battery’s own control electronics limit how many units you can parallel.

Communications and Compatibility

The communications section of this home battery glossary covers how the battery talks to the inverter and to monitoring systems.

CAN bus

A robust two-wire communications standard that links batteries and inverters. Generally, it is the default choice for closed-loop battery communication.

RS485 and RS232

Serial communications standards, also used for battery-to-inverter links and for monitoring. RS485 supports longer cable runs and multiple devices on the same bus.

Modbus

An open protocol that defines how to read and write registers, usually carried over RS485 or TCP. Monitoring systems and home energy management systems rely on it widely.

Closed-loop communication

A setup where the battery continuously reports its state to the inverter, and the inverter adjusts its behaviour in response. It beats open-loop operation, where the inverter infers battery state from voltage alone.

Inverter compatibility

Ultimately, the practical question is whether a given battery will work with a given inverter. Ultimately, matching voltage windows, the communication protocol, and the inverter’s own approved battery list decide it.

Standards and Certification

Compliance language trips up most buyers, so this home battery glossary lists the standards that matter for certification and shipping.

UL 9540

The North American safety standard for energy storage systems. It covers the complete system rather than the cells alone.

UL 1973

The North American safety standard for batteries in stationary applications. It covers cells, modules and packs, including electrical, mechanical and thermal requirements.

IEC 62619

The international safety standard for secondary lithium cells and batteries used in industrial applications, including stationary energy storage.

UN 38.3

The transport-test standard for lithium batteries. Every lithium battery shipment needs a UN 38.3 test summary, and carriers require it before they accept air, sea or rail freight.

MSDS / SDS

The material safety data sheet lists a product’s chemical composition, hazards and handling requirements. Ship lithium batteries with it alongside the UN 38.3 summary.

CE marking

The declaration that a product meets the applicable European Union health, safety and environmental requirements. A manufacturer declares it, backed by test documentation.

CB Scheme

An international mutual-recognition arrangement for electrical product safety test reports. A CB test report lets you obtain national certifications in member countries with less repeat testing.

PSE mark

The Japanese electrical safety marking, and it is required for regulated products sold in Japan.

Customisation Terms

Custom capacity and voltage

Building a battery to a specified energy capacity and nominal voltage rather than selecting a catalogue item. Households pick it where the load profile, backup duration or available space does not match a standard model.

Custom enclosure

Similarly, a housing you specify by size, shape or finish, so the battery fits a particular installation position or matches a room’s appearance.

OEM and ODM

OEM means a manufacturer builds a product to a customer’s specification and brand. ODM means the manufacturer also designs it. The two terms separate who owns the design from who owns the brand.

Branding and private label

You apply a customer’s own brand to a battery — enclosure graphics, display interface, packaging and documentation — so it ships as that brand’s product.

Comparing Systems With This Home Battery Glossary

Before you buy, run the final checklist this home battery glossary ends with. Two systems with the same kWh figure are not equivalent. When you compare home batteries, check four things. First, the depth of discharge at which the capacity figure was quoted, and the cycle life with the temperature at which manufacturers measured it. Second, whether your inverter supports closed-loop communication with that battery. Third, the IP rating against your intended install location. Finally, the certifications the system holds for the market it will serve.

For sizing guidance, see how to size a home battery. Next, home battery installation location covers the installation requirements, and home battery certifications lists the standards held across the range.

Related pages: LiFePO4 cycle life explains how the cycle-life figure in a datasheet is measured and what it means over years of use, home battery performance in winter covers how low temperature changes capacity and charging, LiFePO4 indoor safety covers what to check before installing one inside the home, and sizing a battery for overnight backup works through a single-night runtime example.